This is a powerful sister version of our Linker kit - Temperature and Humidity Sensor. It has more complete and accurate performance. The detecting range of this sensor is 5% RH - 99% RH, and -40°C - 80°C. And its accuracy satisfyingly reaches up to 2% RH and 0.5°C. A professional choice for applications that have relatively strict requirements. | This is a powerful sister version of our Linker kit - Temperature and Humidity Sensor. It has more complete and accurate performance. The detecting range of this sensor is 5% RH - 99% RH, and -40°C - 80°C. And its accuracy satisfyingly reaches up to 2% RH and 0.5°C. A professional choice for applications that have relatively strict requirements. | ||
− | [[File:1-214.jpg]] | + | [[File:1-214.jpg|600px]] |
− | [[File:1-215.jpg]] | + | [[File:1-215.jpg|600px]] |
Line 38: | Line 38: | ||
void setup(void) | void setup(void) | ||
{ | { | ||
− | + | // start serial port | |
− | + | Serial.begin(9600); | |
− | + | Serial.println("DHT22 Library Demo"); | |
− | + | } | |
void loop(void) | void loop(void) | ||
{ | { | ||
DHT22_ERROR_t errorCode; | DHT22_ERROR_t errorCode; | ||
// The sensor can only be read from every 1-2s, and requires a minimum | // The sensor can only be read from every 1-2s, and requires a minimum | ||
− | + | // 2s warm-up after power-on. | |
− | + | delay(2000); | |
+ | Serial.print("Requesting data..."); | ||
+ | errorCode = myDHT22.readData(); | ||
+ | switch(errorCode) | ||
+ | { | ||
+ | case DHT_ERROR_NONE: | ||
+ | Serial.print("Got Data "); | ||
+ | Serial.print(myDHT22.getTemperatureC()); | ||
+ | Serial.print("C "); | ||
+ | Serial.print(myDHT22.getHumidity()); | ||
+ | Serial.println("%"); | ||
+ | // Alternately, with integer formatting which is clumsier but more compact to store and | ||
+ | // can be compared reliably for equality: | ||
+ | // | ||
+ | char buf[128]; | ||
+ | sprintf(buf, "Integer-only reading: Temperature %hi.%01hi C, Humidity %i.%01i %% RH", | ||
+ | myDHT22.getTemperatureCInt()/10, abs(myDHT22.getTemperatureCInt()%10), | ||
+ | myDHT22.getHumidityInt()/10, myDHT22.getHumidityInt()%10); | ||
+ | Serial.println(buf); | ||
+ | break; | ||
+ | case DHT_ERROR_CHECKSUM: | ||
+ | Serial.print("check sum error "); | ||
+ | Serial.print(myDHT22.getTemperatureC()); | ||
+ | Serial.print("C "); | ||
+ | Serial.print(myDHT22.getHumidity()); | ||
+ | Serial.println("%"); | ||
+ | break; | ||
+ | case DHT_BUS_HUNG: | ||
+ | Serial.println("BUS Hung "); | ||
+ | break; | ||
+ | case DHT_ERROR_NOT_PRESENT: | ||
+ | Serial.println("Not Present "); | ||
+ | break; | ||
+ | case DHT_ERROR_ACK_TOO_LONG: | ||
+ | Serial.println("ACK time out "); | ||
+ | break; | ||
+ | case DHT_ERROR_SYNC_TIMEOUT: | ||
+ | Serial.println("Sync Timeout "); | ||
+ | break; | ||
+ | case DHT_ERROR_DATA_TIMEOUT: | ||
+ | Serial.println("Data Timeout "); | ||
+ | break; | ||
+ | case DHT_ERROR_TOOQUICK: | ||
+ | Serial.println("Polled to quick "); | ||
+ | break; | ||
− | |||
− | |||
− | |||
− | |||
(3)Test Results | (3)Test Results | ||
Latest revision as of 11:25, 19 April 2016
Introduction
This is a powerful sister version of our Linker kit - Temperature and Humidity Sensor. It has more complete and accurate performance. The detecting range of this sensor is 5% RH - 99% RH, and -40°C - 80°C. And its accuracy satisfyingly reaches up to 2% RH and 0.5°C. A professional choice for applications that have relatively strict requirements.
Specification
Platforms Supported
- Arduino
- Raspberry Pi
Test
Test tools and test
(1)Test tools
- Arduino UNO x 1
- Linker Base Shield x 1
- Linker temperature & humidity sensor x1
(2)、Program
#include <DHT22.h> // Only used for sprintf #include <stdio.h> // Data wire is plugged into port 7 on the Arduino // Connect a 4.7K resistor between VCC and the data pin (strong pullup) #define DHT22_PIN 7 // Setup a DHT22 instance DHT22 myDHT22(DHT22_PIN); void setup(void) { // start serial port Serial.begin(9600); Serial.println("DHT22 Library Demo"); } void loop(void) { DHT22_ERROR_t errorCode; // The sensor can only be read from every 1-2s, and requires a minimum // 2s warm-up after power-on. delay(2000); Serial.print("Requesting data..."); errorCode = myDHT22.readData(); switch(errorCode) { case DHT_ERROR_NONE: Serial.print("Got Data "); Serial.print(myDHT22.getTemperatureC()); Serial.print("C "); Serial.print(myDHT22.getHumidity()); Serial.println("%"); // Alternately, with integer formatting which is clumsier but more compact to store and // can be compared reliably for equality: // char buf[128]; sprintf(buf, "Integer-only reading: Temperature %hi.%01hi C, Humidity %i.%01i %% RH", myDHT22.getTemperatureCInt()/10, abs(myDHT22.getTemperatureCInt()%10), myDHT22.getHumidityInt()/10, myDHT22.getHumidityInt()%10); Serial.println(buf); break; case DHT_ERROR_CHECKSUM: Serial.print("check sum error "); Serial.print(myDHT22.getTemperatureC()); Serial.print("C "); Serial.print(myDHT22.getHumidity()); Serial.println("%"); break; case DHT_BUS_HUNG: Serial.println("BUS Hung "); break; case DHT_ERROR_NOT_PRESENT: Serial.println("Not Present "); break; case DHT_ERROR_ACK_TOO_LONG: Serial.println("ACK time out "); break; case DHT_ERROR_SYNC_TIMEOUT: Serial.println("Sync Timeout "); break; case DHT_ERROR_DATA_TIMEOUT: Serial.println("Data Timeout "); break; case DHT_ERROR_TOOQUICK: Serial.println("Polled to quick "); break;
(3)Test Results