| align="center" style="width:200px"| Product Name
+
| align="left" style="width:300px"| Product Name
| align="center" style="width:400px"| McLaren (Homgplug serial adapter)
+
| align="left" style="width:400px"| McLaren (Homgplug serial adapter)
 
|-
 
|-
| align="center" rowspan=6| Interface
+
| align="left" rowspan=6| Interface
| align="center"| 3.3V TTL UART; Optional interface cards:
+
| align="left"| 3.3V TTL UART; Optional interface cards:
 
|-
 
|-
| align="center"| RS232 (model/ordering no: UART-RS232)
+
| align="left"| RS232 (model/ordering no: UART-RS232)
 
|-
 
|-
| align="center"| RS485 (model/ordering no: UART-RS485)
+
| align="left"| RS485 (model/ordering no: UART-RS485)
 
|-
 
|-
| align="center"| USB (model/ordering no: UART-USB)
+
| align="left"| USB (model/ordering no: UART-USB)
 
|-
 
|-
| align="center"| Ethernet (model/ordering no: UART-Ethernet)
+
| align="left"| Ethernet (model/ordering no: UART-Ethernet)
 
|-
 
|-
| align="center"| Zigbee (model/ordering no: Xbee)
+
| align="left"| Zigbee (model/ordering no: Xbee)
 
|-
 
|-
| align="center" rowspan=3| Communication Line Voltage
+
| align="left" rowspan=3| Communication Line Voltage
| align="center"| 230VAC/50Hz
+
| align="left"| 230VAC/50Hz
 
|-
 
|-
| align="center"| 110VAC/60Hz
+
| align="left"| 110VAC/60Hz
 
|-
 
|-
| align="center"| 0-400V DC
+
| align="left"| 0-400V DC
 
|-
 
|-
| align="center"| Supply Voltage
+
| align="left"| Supply Voltage
| align="center"| 5V-12V DC,3A
+
| align="left"| 5V-12V DC,3A
 
|-
 
|-
| align="center"| Modulation
+
| align="left"| Modulation
| align="center"| OFDM (Homeplug 1.0 Compatible)
+
| align="left"| OFDM (Homeplug 1.0 Compatible)
 
|-
 
|-
| align="center"| Error Correction
+
| align="left"| Error Correction
| align="center"| FEC(Forward Error Correction)
+
| align="left"| FEC(Forward Error Correction)
 
|-
 
|-
| align="center"| Data rate on Powerline
+
| align="left"| Data rate on Powerline
| align="center"| 5Mbps (throughput)
+
| align="left"| 5Mbps (throughput)
 
|-
 
|-
| align="center"| Maximum packet data length
+
| align="left"| Maximum packet data length
| align="center"| 300 bytes
+
| align="left"| 300 bytes
 
|-
 
|-
| align="center"| Transmission distance
+
| align="left"| Transmission distance
| align="center"| 300 feets(no repeater)
+
| align="left"| 300 feets(no repeater)
 
|-
 
|-
| align="center"| Support nodes number
+
| align="left"| Support nodes number
| align="center"| 65535
+
| align="left"| 65535
 
|-
 
|-
| align="center" rowspan=3| LED
+
| align="left" rowspan=3| LED
| align="center"| Power Line Activity LED  
+
| align="left"| Power Line Activity LED  
 
|-
 
|-
| align="center"| System LED
+
| align="left"| System LED
 
|-
 
|-
| align="center"| Serial Port LED
+
| align="left"| Serial Port LED
 
|}
 
|}
  

Revision as of 08:27, 11 December 2012

Introduction

LinkSprite’s broadband powerline communication module McLaren are consisted of a McLaren motherboard, UART-RS232 daughter board, UART-RS485 daughter board, UART-USB daughter board, UART-Zigbee daughter board and UART-Ethernet daughter board.

On the McLaren motherboard, there is a 20-pin 2mm spacing receptacle, users can choose different daughter boards based on the interface needs.

The McLaren motherboard also support DIP by optional pins that can be used to directly plug to user’s board without doing screwing. The interface board signals such as RS232/RS485/USB signals are also routed back to motherboard through the 20-pin receptacle, and again to users’ board through these DIP pins.

McLaren are transceiver modules designed to send / receiver serial data over the powerline network. McLaren is designed to transparently move serial data over the powerline network, and achieves the target of replacing cables by the ubiquitous powerline network.

Features

  • AC and DC powerline Communications
  • Fully transparent mode, plug and play coming out of the box without the need to do any programming.
  • HomePlug1.0
  • 5Mbps throughput on the power line
  • Built-in error correction codes.
  • Built-in repeater function to extend the coverage.
  • Physical and logic address
  • AT commands used for advanced configuration.
  • 3.3V TTL UART, Optional RS232, RS485. USB, Ethernet, Zigbee interfaces
  • Low power
  • RoHS

Application Ideas

  • AMR
  • Industry manufacture and control
  • Safeguard, fire alarm, smoke alarm
  • Collect and transmit instrument data
  • Safeguard and monitor
  • Home automation
  • Solar/Wind electricity generation system
  • Low latency servo control

Cautions

Schematic

Specification

Product Name McLaren (Homgplug serial adapter)
Interface 3.3V TTL UART; Optional interface cards:
RS232 (model/ordering no: UART-RS232)
RS485 (model/ordering no: UART-RS485)
USB (model/ordering no: UART-USB)
Ethernet (model/ordering no: UART-Ethernet)
Zigbee (model/ordering no: Xbee)
Communication Line Voltage 230VAC/50Hz
110VAC/60Hz
0-400V DC
Supply Voltage 5V-12V DC,3A
Modulation OFDM (Homeplug 1.0 Compatible)
Error Correction FEC(Forward Error Correction)
Data rate on Powerline 5Mbps (throughput)
Maximum packet data length 300 bytes
Transmission distance 300 feets(no repeater)
Support nodes number 65535
LED Power Line Activity LED
System LED
Serial Port LED

Pin definition and Rating

Mechanic Dimensions

Usage

Hardware Installation

Programming

FAQ

Please list your question here:

Support

If you have questions or other better design ideas, you can go to our forum to discuss or creat a ticket for your issue at linksprite support.

Resources

How to buy

See Also

Other related products and resources.

Licensing

This documentation is licensed under the Creative Commons Attribution-ShareAlike License 3.0 Source code and libraries are licensed under GPL/LGPL, see source code files for details.