Difference between revisions of "Dust Sensor"

From LinkSprite Playgound
Jump to: navigation, search
(Features)
(Specification)
Line 37: Line 37:
 
* Arbitrary operation may cause unexpected damage.  
 
* Arbitrary operation may cause unexpected damage.  
 
* Pins VR1 and VR2 come preset. Please DON'T change the default configuration.
 
* Pins VR1 and VR2 come preset. Please DON'T change the default configuration.
 
==Specification==
 
 
{| border="1" cellspacing="0" width="80%"|-
 
!Items
 
!Min
 
!Norm
 
!Max
 
!Unit
 
|-
 
| align="center" | VCC
 
| align="center" | 4.75
 
| align="center" | -
 
| align="center" | 5.25
 
| align="center" | V
 
|-
 
| align="center" | Standby Current Supply
 
| align="center" | -
 
| align="center" | 90
 
| align="center" | -
 
| align="center" | mA
 
|-
 
| align="center" | Detectable range of concentration
 
| align="center" | -
 
| align="center" | 0~28,000
 
| align="center" | -
 
| align="center" | pcs/liter
 
|-
 
| align="center" | Operating Temperature Range 
 
| align="center" | 0
 
| align="center" | -
 
| align="center" | 45
 
| align="center" | °C
 
|-
 
| align="center" | Output Method
 
| align="center" colspan="5" | Negative Logic, Digital output,Hi over 4.0V(Rev.2) Lo: under 0.7V
 
|-
 
| align="center" | Detecting the particle diameter
 
| align="center" colspan="5" | >1 um
 
|-
 
| align="center" | Dimensions
 
| align="center" colspan="5" |59(W) × 45(H) × 22(D) [mm]
 
|-
 
| align="center" | Humidity Range
 
| align="center" colspan="5" |95%rh or less
 
|}
 
 
<br>
 
  
 
== Usage  ==
 
== Usage  ==

Revision as of 10:01, 29 July 2014



Introduction

This Dust Sensor measures the Particulate Matter level in air by counting the Lo Pulse Occupancy time(LPO time) in given time unit. LPO time is in proportion to PM concentration. This sensor can provide you pretty reliable data for your PM2.5 project or air purifier system because it's still responsive to particulates whose diameter is 1um.


DSM501 dust sensor.jpg

Features

  • Supply voltage : DC5V±10%
  • Power consumption : 90mA
  • Operating temperature range : -10~ +65 C
  • Operating humidity range : 95%RH or less (without dew condensation)
  • Recommend storage condition : -20~ +80C
  • Dimension : W59 * H45 * D20 (mm)
  • Detectable particle size : approx. 1? (minimum)
  • Detectable range of concentration : 0 ~ 1.4?/?
  • Output signal : PWM (pulse width modulation)
  • Time for stabilization : 1 minute after power turned on
  • Sensor characteristics : To be maintained in between the upper limit and lower limit of the standard dust sensor unit

Application Ideas

Cautions

  • Please keep it upright.
  • 3 min preheat time is required when used at the first time.
  • Arbitrary operation may cause unexpected damage.
  • Pins VR1 and VR2 come preset. Please DON'T change the default configuration.

Usage

The following article shows how to use dust sensor on pcDuino:

pcDuino can help You Measure Air Particle Pollution PM2.5

Resources

Example of uploading data from dust sensor to Cosm.